GRV150-EP Industrial Ozone Generator
Industrial Ozone Generator, water-cooled, Virola type, designed to operate with LOX or PSA, with PLC control and touch screen. Ozone production of 150KgO3/h, at 150g/Nm3 concentration. 400V, 50Hz, 1.125kW.
Highly Recommended
2-year warranty extendable
Manufacturing time: Consult
Industrial Ozone Generator
Technical specifications
What is it used for?
This ozone generator is used for powerful wastewater treatment and disinfection (WWTP), and public water purification (DWTP). It is also used in bleaching processes in the textile and paper industries. It is also used in fish farms, aquariums, recovery of lakes and agricultural ponds, irrigation water, etc...
Product Details
Ozone Generation system | Una Virola de KgO3/h, con 150 dieléctricos de borosilicato. Refrigerado por Glicol. |
Control | Por PLC con Pantalla Táctil 7" SIEMENS. Gestor de alarmas y mantenimientos. Regulación de potencia y caudal por lazo PID. |
Included in the packaging | Manual de Usuario |
Technical Valves | Válvula motorizada de entrada de oxígeno, Mano reductor con filtro en la entrada, Válvula proporcional para ajuste automático de caudal, Válvula motorizada de ozono de salida. Válvula de seguridad en la virola. |
Sensors | Punto de Rocío del Oxígeno entrante. Caudal, Temperatura y Presión de gas Ozono resultante. Flujo y Temperatura de caudal de Refrigeración. Fugas de Ozono. Apertura de Puerta. |
Refrigeration | El agua de refrigeración debe ser suministrado por el cliente. El equipo no incluye enfriadora. Puede adquirirla opcionalmente. También puede trabajar en circuito cerrado con intercambiador de calor. Vea Accesorios los modelos recomendados. |
Oxygen concentrator | El oxígeno debe ser suministrado por el cliente, desde LOX o PSA. El equipo no incluye PSA. |
Communication | ON remoto cableado, Relés de estado (Iniciado, Generando, Fallo), Permite comunicación ModBus. Router VPN incluido para Acceso Remoto con Control total. |
Power supply | 380 -460 V, 3 P, 50-60 Hz |
Air/Oxygen flow | Necesita 135 Nm3/h a 3-5 bares a 5-30ºC |
Recirculation Flow | Necesita 40 m3/h a 1 bar a 15-22ºC |
Ozone concentration | Máxima = 200 g/Nm3 | Óptima = 148 g/Nm3 |
Hydraulic connexion | IN/OUT DN100 |
Dimensions |
Generador de Ozono: 4250 x 1150 x 2000 mm (Ancho x Profundo x Alto) PSU: 4800 x 1000 x 2160 mm (Ancho x Profundo x Alto) |
Electric Power | 150 kW |
Gas connection | IN/OUT DN50 |
Weight |
Generador de Ozono: 2900 kg PSU: 4000 kg |
Ozone Production | 150 kg O3/h |
Source gas | El equipo necesita un suministro de oxígeno bien LOX o PSA. |
Gas quality | 95-99% de pureza de oxígeno, secado de -40ºC Punto de Rocío. |
Room fittings | La sala debe estar bien ventilada, y prever sistema de extracción para caso de fugas. Instalar cartel con las advertencias de seguridad. |
Humidity | < 85 % |
Room temperature | 5 - 35ºC |
Working pressure | 0,6 - 1,4 bars |
Quality of the water that is refrigerated | Agua osmotizada + Glicol |
Others | Admite venturi a la salida. |
Warranty | 2 años ampliable indefinidamente, con contrato de mantenimiento |
Last revision | 2023 |
Made by | ZonoSistem |
Made in | España |
Certificates | CE, EUTOA, BIOCIDE |
Sold from | 2019 |
UFI number | G000-W09P-Y00M-TV8V |
Funcioning
When the ozone generator receives a start order, it opens the inlet valve allowing oxygen to enter the equipment. The range of desired oxygen pressure will be maintained. Once the pressure is regulated, the oxygen is conducted to the ozone generation system, where the oxygen is exposed to a strong electric field creating the ozone molecule, a very reactive and oxidizing gas. The gas flowmeter continuously measures the ozone flow rate which is adjusted to the desired value. The power in kw of the equipment can be varied manually on the screen or through an external 4-20mA signal.
If it does not detect water flow, oxygen flow, or the cooling temperature is not adequate, the generator will give an alarm and stop for safety
Documentation incluided
Safety manual.
User manual, installation and commissioning.
Maintenance manual.
Declaration of Conformity.
Certificate of guarantee.
Compliance with biocidal regulations.
Our Quality Test results.
Technology
The GRV's ozone generation technology is based on high-frequency corona discharge, with a 50,000V-resistant borosilicate dielectric. It works with voltages from 5,000 to 10,000v, and at a frequency of higher than 5khz. Made of materials with high resistance to ozone, 316L stainless steel, Viton and Teflon gaskets.